The Poolstore Bowman Single Phase Heater should only
be installed by competent trade staff with the appropriate
qualifications to carry out the work and must be installed
in accordance with all relevant statutory requirements
governing the installation.
This equipment must be installed with an isolation switch
in the fixed wiring as required by AS3000 and it is designed
to operate with the main axis of the water chamber in
a vertical position.
The direction of the flow is such that the incoming water
supply will enter the body at the lower union joint and
leave the body at the upper union joint.
Please note that the reduction of the union tail piece
from 50mm nominal size to 40mm nominal size will have
no adverse effect on the heaters operation and this option
should be determined by the trade person undertaking its
installation.